Last I encountered an error where running build-index from toolkit would give the following 2 lines but it wouldn't rebuild index and do nothing.
The program exiting with exit code: 0.
Data import process completed successfully with no errors.
If you need to directly run index on SOLR server: This is the command
http://localhost/solr/MC_10051_CatalogEntry_en_US/dataimport?command=full-import
To Monitor:
http://localhost/solr/MC_10051_CatalogEntry_en_US/dataimport?command=status
Once I ran directly on SOLR, full-import, it gave the errors.
In this particular case, it gave heap error and had to increase 512 MB to 1024 MB in WAS admin console.
The program exiting with exit code: 0.
Data import process completed successfully with no errors.
If you need to directly run index on SOLR server: This is the command
http://localhost/solr/MC_10051_CatalogEntry_en_US/dataimport?command=full-import
To Monitor:
http://localhost/solr/MC_10051_CatalogEntry_en_US/dataimport?command=status
Once I ran directly on SOLR, full-import, it gave the errors.
In this particular case, it gave heap error and had to increase 512 MB to 1024 MB in WAS admin console.